WENZEL Logo

exaCT S - CTS0924

Machine data

Manufacturer
Wenzel
Type
exaCT-S
Year of manufacture
2021
Location
Wenzel

Measuring range

X-axis [mm]
Y-axis [mm]
Z-axis [mm]

Uncertainty of measurement

MPEE [μm]
MPESD = 5.0µm + (L / 40mm) according to VDI/VDE 2630 sheet 1.3 (without maximum value limit)
MPEP [μm]
MPETHP** [μm]
MPETHP** [sec]
Temperature range
20°C +/-2 K
Temperature gradient
According to DIN EN ISO 10360-2

Equipment

Control
CT master computer, CT reconstruction computer
Touch probe option 1
Touch probe option 2
Touch probe option 3
Software option 1
WM | Quartis 4 CT ; WM | exaCT Control; WM | exaCT Volume; WM | exaCT Analysis Standard Package
Software option 2
Software option 3
Accessories
Other Option 1
Other Option 2
Other Option 3

Description

Description / Description

  • Ergonomic desktop CT with integrated control cabinet
  • Hohe Leistung von 130 kV mit Wartungsfreier Strahlquelle / High power of 130 kV with maintenance-free radiation source
  • Easy operability and high performance oft he application software / Easy operability and high performance oft he application software
  • Fast set-up of workpieces thanks to integrated video cameras and special software features
  • Hochauflösender Detektor für maximale Detailerkennbarkeit / High resolution detector for maximum detail detectability
  • Strahlenschutz entsprechend Vollschutzgerät nach StrSchV /Full radiation protection chamber based on German RÖV regulation
  • Multifunktions-Signalleuchte /Multifunctional system status signal lamp

Highlights

  • Comprehensive Software Package / Comprehensive Software Package
  • Measuring chamber video transmission
  • Vibration damping of the measuring chamber (elastomer)

 

Machine profile

Betriebstemperatur /Operating temperature: 18°C - 30°C 1) Relative humidity: 40% - 60%

1) For metrological applications a smaller temperature range is required For metrological applications a smaller temperature range is required

Subject to prior sale and changes in design and specification without prior notice. Machine may show signs of use.
.
www.wenzel-group.com

WENZEL Metrology GmbH | Werner-Wenzel-Straße | 97859 Wiesthal | Germany
Phone: +49 6020 201-8888 | Fax +49 6020 201-8299 | E-mail: retrofit@wenzel-metrology.de

Machine data

Manufacturer
Wenzel
Type
exaCT-S
Year of manufacture
2021
Location
Wenzel

Measuring range

X-axis [mm]
Y-axis [mm]
Z-axis [mm]

Uncertainty of measurement

MPEE [μm]
MPESD = 5.0µm + (L / 40mm) according to VDI/VDE 2630 sheet 1.3 (without maximum value limit)
MPEP [μm]
MPETHP** [μm]
MPETHP** [sec]
Temperature range
20°C +/-2 K
Temperature gradient
According to DIN EN ISO 10360-2

Equipment

Control
CT master computer, CT reconstruction computer
Touch probe option 1
Touch probe option 2
Touch probe option 3
Software option 1
WM | Quartis 4 CT ; WM | exaCT Control; WM | exaCT Volume; WM | exaCT Analysis Standard Package
Software option 2
Software option 3
Accessories
Other Option 1
Other Option 2
Other Option 3

Description

Description / Description

  • Ergonomic desktop CT with integrated control cabinet
  • Hohe Leistung von 130 kV mit Wartungsfreier Strahlquelle / High power of 130 kV with maintenance-free radiation source
  • Easy operability and high performance oft he application software / Easy operability and high performance oft he application software
  • Fast set-up of workpieces thanks to integrated video cameras and special software features
  • Hochauflösender Detektor für maximale Detailerkennbarkeit / High resolution detector for maximum detail detectability
  • Strahlenschutz entsprechend Vollschutzgerät nach StrSchV /Full radiation protection chamber based on German RÖV regulation
  • Multifunktions-Signalleuchte /Multifunctional system status signal lamp

Highlights

  • Comprehensive Software Package / Comprehensive Software Package
  • Measuring chamber video transmission
  • Vibration damping of the measuring chamber (elastomer)

 

Machine profile

Betriebstemperatur /Operating temperature: 18°C - 30°C 1) Relative humidity: 40% - 60%

1) For metrological applications a smaller temperature range is required For metrological applications a smaller temperature range is required

Subject to prior sale and changes in design and specification without prior notice. Machine may show signs of use.

Make an enquiry about this machine

exaCT S - CTS0924
Albania
Algeria
Argentina
Australia
Bahrain
Bangladesh
Belgium
Bosnia and Herzegovina
Brazil
Bulgaria
Chile
China
Costa Rica
Germany
Dubai
Denmark
Ecuador
Estonia
Finland
France
Greece
India
Indonesia
Iraq
Iran
Ireland
Israel
Italy
Japan
Yemen
Jordan
Canada
Canada
Colombia
Croatia
Kuwait
Latvia
Lebanon
Lithuania
Luxembourg
Libya
Malaysia
Morocco
Macedonia
Mexico
Montenegro
Nepal
New Zealand
Netherlands
Norway
Oman
Pakistan
Philippines
Poland
Portugal
Quatar
Romania
Russia
Saudi Arabia
Sweden
Switzerland
Serbia
Singapore
Slovakia
Slovenia
Spain
Sri Lanka
South Africa
South Korea
Taiwan
Thailand
Czech republic
Tunisia
Turkey
USA
Hungary
Venezuela
United Arab Emirates
United Kingdom
Vietnam
Yemen
Egypt
Austria
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Download datasheet of this machine

WENZEL Logo
Download

Are you looking for an inexpensive used measuring device?

We will search for your desired measuring machine among all the used machines listed in our database.

To the form

You would like to sell your used measuring device?

We are happy to support you in the sale of your measuring machine.

To the form